110.26 -- Spaces About Electrical
Equipment
Who Cut My
Wires?
What's
Wrong
Here?
Code Q&A
Code Quiz
NFPA Announces Corrections to 2005
NEC
Who Do You
Call?
|
|
About this Newsletter
|
This twice-a-month e-newsletter is brought to you from the
publisher of EC&M magazine. CodeWatch will:
Let you know what could be changing in the Code®.
Help you brush up on your ability to apply the Code®.
Test your knowledge of the Code® with a Q&A format.
Introduce you to the people who vote on the rule changes.
Provide information on upcoming Code® seminars and shows.
Give you an opportunity to sound off on Code®-related issues.
We want to make sure we're providing you with the content you need to
better manage your business or enhance your technical skills. E-mail us and
let us know what you want to see in future issues of this e-newsletter.
We will do our best to address your request in a future issue of
CodeWatch.
|
Subscriptions
|
|
To sign up
for your free subscription, click here: Subscribe
To unsubscribe from this newsletter click here: Unsubscribe
To get this newsletter in a different format (Text, AOL or HTML),
or to change your e-mail address, please visit your profile page to change your delivery
preferences.
|
Back Issues
|
|
Missed an
issue? Visit the
CodeWatch archive on EC&M's Web site.
|
Tell a friend about CodeWatch
|
|
Do you know
of someone who'd like to receive CodeWatch? Visit the subscriber site, enter their e-mail
address and spread the wealth!
|
Advertising
|
To find out
how to advertise in this newsletter, e-mail David Miller or call
him
at (312) 840-8497.
The designations "National Electrical Code” and “NEC” refer to the
National Electrical Code®, which is a registered trademark of the
National Fire Protection Association.
|
| | | | |
|
Top 2005 Code Changes
110.26 --
Spaces
About Electrical Equipment
By Mike Holt
The requirement that equipment rated 1,200A or more had
to be more than 6 feet wide before an entrance was required at each end
of the working space was removed.
What the Code says: (C) Entrance to
Working Space
(2) Large Equipment. For equipment rated 1,200A or more and
more than 6 ft wide, an entrance measuring not less than 24
in.
wide and 61/2 ft high is required at each end of
the working space. Where the entrance to the working space has a door,
the door must open out and be equipped with panic hardware or other
devices that open under simple pressure. (Click here
for an illustration of the change.)
Behind the change: The argument for the change was that the
size of the arc blast is directly related to the ampere rating of the
equipment, not the physical width of the equipment.
ADVERTISEMENT
The
Fluke T5 Electrical Testers allow you to troubleshoot faster and safer
than traditional solenoid testers. They let you check voltage,
continuity and current with one compact tool. With the T5, all you have
to do is select volts, ohms, or current and the tester does the rest.
OpenJaw™ current lets you check current up to 100A - without
breaking the circuit.
http://us.fluke.com/usen/products/Fluke++T5.htm?catalog_name=FlukeUnitedStates
Nightmare Installations
Who Cut My Wires?
When I happened to stop by a newly remodeled grocery
store where we had completed the temperature controls the previous
week,
I was met instantly by a hopping-mad manager. Apparently the place had
been cold for several days. A quick measurement of the resistance of
the
thermistor sensor at the panel showed it was an open circuit. The store
was so large that it had four far-flung temperature sensors in a
series/parallel circuit, which is equal to one, but somewhere out there
a wire had come loose and opened the loop. I quickly wired back in one
sensor in the center of the store to get the heating system going. I
then opened up several ceiling tiles and found four of our wires had
been cut off about 10 feet from one of the sensors. Apparently the
people who wired the public address system had run out of wire to
complete their work so they cut our wires and used quite a long section
of them to connect some speakers. The public address contractor
couldn't
believe that his people would do such a thing, but he came out to
replace the work when I mentioned lawsuits and backcharges.
Daniel Horon
Sparta, Mich.
Send your 200-word story to us and it may
appear in a future issue of CodeWatch. Authors of stories chosen will
receive $25.
ADVERTISEMENT
Cool Electronic Cabinets
Low cost Cabinet Coolers stop electronic control downtime due to heat,
dirt and moisture. UL Listed Cabinet Coolers produce 20 degree
Fahrenheit air from an ordinary supply of compressed air to cool
electrical controls. Thermostat control minimizes air usage. Maintains
the NEMA 4, 4X (stainless steel) and 12 rating of the enclosure. Web
site offers detailed information, downloadable drawings and PDF
literature.
www.exair.com
Code Challenge
What's Wrong Here?
By Joe Tedesco
How does this
installation violate the NEC?
Hint: This EMT and conduit body is installed in a wet
location.
Code Q&A
By Mike Holt
Q. Does the Code permit a circuit breaker to be
installed horizontally?
See the answer.
Code Quiz
By Steven Owen
In a newly designed multi-family dwelling unit
(208/120V, 3-phase, 4-wire system) the load on the service
grounded "neutral" conductor is calculated to be 475A. What is the
demand load, if any, on the grounded "neutral" conductor of this
system?
- 392.5A
- 200A
- 475A
- 406.25A
Visit EC&M's Web
site
for the answer and explanation.
ADVERTISEMENT
Are you paying too much for enclosed
starters?
Cerus builds quality HVAC and industrial starters that boost your
profit. 5 year contactor warranty backs up our quality. Custom
staters, pump panels, drives and more. Get all the facts at www.cerusind.com
or call 1-800-962-3787 for a FREE catalog.
Code News Updates
NFPA Announces
Corrections to 2005 NEC
For those of you who were first in line to buy the
latest Code book, it's time to get out your red pen and make some
homemade revisions. NFPA just released a list of errata
that apply to the first edition of the 2005 NEC. The full list of
corrections can be found at the
NFPA site. Although many of the errors involve transposed numbers
and letters, some could have a significant effect on how Code
requirements are interpreted.
If you're unsure whether you have a first edition Code book, check
the line of numbers that appear at the bottom of the inside front
cover.
If the last number is "1," you have a first edition.
ADVERTISEMENT
www.NECcode.com
The National Electrical Code Internet Connection, the No. 1
rated Code Web site in the world, offers the following FREE products:
Books, Code Quiz, DVDs, Graphics for PowerPoint, Newsletter, Online
Training, Posters, Simulated Exams, Software, Video clips, and Videos
Visit www.NECcode.com and stay
current with important industry issues.
Speak Out
Who Do You Call?
As the NFPA's recently published errata proves, even
the
NEC makes mistakes sometimes. When you encounter something in the Code
that doesn't quite make sense, whom do you go to for clarification?
Visit EC&M's Web site to
tell
us.
You may want to tell your lazy neighbor to take his Christmas lights
down every Spring, but the majority of CodeWatch readers think that's
the electrical inspector's responsibility. Last issue's poll
question
received an usually high number of responses, and 56% of you think it's
up to the inspector to inform homeowners of the NEC's 90-day
restriction. A CodeWatch reader, Kid Stevens, suggested a different
approach: "Send a letter or a code notification to the Local Power
Utilities to include a message to the local users in the bill. This
message will apprise the end users of Code changes that effect them
directly." Food for thought.
|
|
You are subscribed to this newsletter as <*email*>
For questions concerning delivery of this
newsletter, please contact our Customer Service Department at:
US Toll Free: (866) 505-7173
International: (402) 505-7173
or custserv@newsletter.primediabusiness.com
Primedia Business Magazines & Media
9800 Metcalf Avenue
Overland Park, KS 66212
Copyright 2004, PRIMEDIA. All rights reserved. This article is
protected
by United States copyright and other intellectual property laws and may
not be reproduced, rewritten, distributed, re-disseminated,
transmitted,
displayed, published or broadcast, directly or indirectly, in any
medium
without the prior written permission of Primedia Business Magazines &
Media Inc.
|
|