Article 682 -- Natural and
Artificially Made Bodies of Water
Tap Trouble
What's
Wrong
Here?
Code Q&A
Code Quiz
Code
Committee Call-Up
Water Logged?
Grounding vs Bonding Seminar
|
|
About this Newsletter
|
This twice-a-month e-newsletter is brought to you from the
publisher of EC&M magazine. CodeWatch will:
Let you know what could be changing in the Code®.
Help you brush up on your ability to apply the Code®.
Test your knowledge of the Code® with a Q&A format.
Introduce you to the people who vote on the rule changes.
Provide information on upcoming Code® seminars and shows.
Give you an opportunity to sound off on Code®-related issues.
We want to make sure we're providing you with the content you need to
better manage your business or enhance your technical skills. E-mail us and
let us know what you want to see in future issues of this e-newsletter.
We will do our best to address your request in a future issue of
CodeWatch.
|
Subscriptions
|
|
To sign up
for your free subscription, click here: Subscribe
To unsubscribe from this newsletter click here: Unsubscribe
To get this newsletter in a different format (Text, AOL or HTML),
or to change your e-mail address, please visit your profile page to change your delivery
preferences.
|
Back Issues
|
|
Missed an
issue? Visit the
CodeWatch archive on EC&M's Web site.
|
Tell a friend about CodeWatch
|
|
Do you know
of someone who'd like to receive CodeWatch? Visit the subscriber site, enter their e-mail
address and spread the wealth!
|
Advertising
|
To find out
how to advertise in this newsletter, e-mail David Miller or call
him
at (312) 840-8497.
The designations "National Electrical Code” and “NEC” refer to the
National Electrical Code®, which is a registered trademark of the
National Fire Protection Association.
ADVERTISEMENT

ADVERTISEMENT

|
| | | | |
|
Top 2005 Code Changes
Article 682
-- Natural and Artificially Made Bodies of Water
By Mike Holt
This new article covers the installation of electrical
wiring
for, in, and adjacent to natural or artificially made bodies of water
not covered by Article 680. This includes aeration ponds, fish farm
ponds, storm retention basins, sewage treatment ponds, and irrigation
channels.
Behind the change: The scope of Article 680 was insufficient
for covering such bodies of water, so only the requirements in Chapters
1 and 4 applied. Instead of expanding the Article, it was decided to
add
Article 682.
ADVERTISEMENT
Achieve Your Performance Goals
Anticipate, prevent and troubleshoot motors, electrical and equipment
maintenance with fast, accurate non-contact temperature measurements
with Fluke infrared thermometers. www.fluke.com/codewatch_temp
Nightmare Installations
Tap Trouble
I once had the job of rewiring an older home that had
knob and tube wiring. The fuse box had been replaced with a circuit
breaker panel, and some new branch circuits had been added for the
electric range and clothes dryer. There was a studio apartment below
the
house in what at one time had been the garage. The branch circuit
wiring
there was NMS cable, but it was energized from one of the old knob and
tube circuits connected to a circuit breaker. My intention was to
locate
the "home run" outlet box, route a new circuit to it and thus hot-up
the
room. After removing all the devices from their outlet boxes, I
reenergized the circuit. To my surprise, all the outlet boxes still had
a "hot" wire in them. The previous installer had tapped into the knob
and tube in the floor space of the room above and drop circuit
extensions to each box. So much for an easy fix.
Paul Bramblett
Houston
Send your 200-word story to us and it may
appear in a future issue of CodeWatch. Authors of stories chosen will
receive $25.
ADVERTISEMENT
Cool Electronic Cabinets
Prevent hot weather failures that can affect production. UL Listed
Cabinet Coolers produce 20 degree Fahrenheit air from an ordinary
supply
of compressed air to cool electrical controls. Thermostat control
minimizes air usage. Maintains the NEMA 4, 4X (stainless steel) and 12
rating of the enclosure. Web site offers detailed information,
downloadable drawings and PDF literature.
www.exair.com/15/540_09a.htm
Code Challenge
What's Wrong Here?
By Joe Tedesco
Got a guess for how this installation violates the NEC?
Visit EC&M's
Web site to see the answer.
Hint: This green light means "stop."
Code Q&A
By Mike Holt
Q. Is a switch that is located in a bedroom but
controls an outside light required to be AFCI protected?
Visit EC&M's Web
site to see the answer.
Code Quiz
By Steven Owen
When installing a Combustible Gas Detection System (in
industrial establishments with restricted public access, and using
qualified personnel to service the installation) as a protection
technique in a Class I hazardous (classified) location of Article 501,
or a Zone location of Article 505, all but which of the following items
shall be documented?
- Purchase date / installation date
- Calibration frequency
- Alarm and shutdown criteria
- Installation location
- Type of detection equipment and its installation listing
Visit EC&M's Web
site
for the answer and explanation.
ADVERTISEMENT
www.NECcode.com
The National Electrical Code Internet Connection, the No. 1
rated Code Web site in the world, offers the following FREE products:
Books, Code Quiz, DVDs, Graphics for PowerPoint, Newsletter, Online
Training, Posters, Simulated Exams, Software, Video clips, and Videos
Visit www.NECcode.com and stay
current with important industry issues.
Code News Update
Code Committee
Call-Up
Got some extra time on your hands? Looking to put some
of your vast knowledge of the electrical field to use? NFPA is looking
for new members for several of its committees, including the following:
Committee on Electrical Equipment of Industrial Machinery
Committee on Electrical Systems Maintenance
Committee on Health Care Facilities - Electrical Equipment
Committee on Health Care Facilities - Electrical Systems
Anyone interested in serving can download the application form at NFPA's Web
site.
Speak Out
Water Logged?
The 2005 NEC added yet more requirments for electrical
installations near water. Was it necessary to create a new article
rather than put the requirements in Article 680? Visit EC&M's Web site to tell us.
CodeWatch readers had a wide range of opinions as to what to do with
210.12 on AFCIs. Visit EC&M's Web
site
to read their responses.
Shows and Events
Grounding vs
Bonding Seminar
Grounding and bonding of electrical systems, sensitive
electronic, and communications equipment is the most important and
least
understood activity in the electrical, data processing, and
communications industry. At four two-day seminars, Code expert Mike
Holt
will explain the basics as well as the advance concepts necessary to
understand the practical grounding and bonding rules in the NEC for
systems not over 600V. Download
the conference brochure for specific dates and locations.
|
|
You are subscribed to this newsletter as <*email*>
For questions concerning delivery of this
newsletter, please contact our Customer Service Department at:
US Toll Free: (866) 505-7173
International: (402) 505-7173
or custserv@newsletter.primediabusiness.com
Primedia Business Magazines & Media
9800 Metcalf Avenue
Overland Park, KS 66212
Copyright 2005, PRIMEDIA. All rights reserved. This article is
protected
by United States copyright and other intellectual property laws and may
not be reproduced, rewritten, distributed, re-disseminated,
transmitted,
displayed, published or broadcast, directly or indirectly, in any
medium
without the prior written permission of Primedia Business Magazines &
Media Inc.
|
|