Article 800 -- Communications
Circuits, Part IV. Grounding Methods, 800.100 Cable and Primary
Protector Grounding
The
Case of the Mysterious Switch
What's
Wrong
Here?
Code Q&A
Code Quiz
Seattle Adopts 2005 NEC
|
|
About this Newsletter
|
This twice-a-month e-newsletter is brought to you from the
publisher of EC&M magazine. CodeWatch will:
Let you know what could be changing in the Code®.
Help you brush up on your ability to apply the
Code®.
Test your knowledge of the Code® with a Q&A format.
Introduce you to the people who vote on the rule changes.
Provide information on upcoming Code® seminars and
shows.
Give you an opportunity to sound off on
Code®-related
issues.
We want to make sure we're providing you with the content you need to
better manage your business or enhance your technical skills. E-mail us and
let us know what you want to see in future issues of this e-newsletter.
We will do our best to address your request in a future issue of
CodeWatch.
|
Subscriptions
|
|
To sign up
for your free subscription, click here: Subscribe
To unsubscribe from this newsletter click here: Unsubscribe
To get this newsletter in a different format (Text, AOL or HTML),
or to change your e-mail address, please visit your profile page to change your delivery
preferences.
|
Back Issues
|
|
Missed an
issue? Visit the
CodeWatch archive on EC&M's Web site.
|
Tell a friend about CodeWatch
|
|
Do you know
of someone who'd like to receive CodeWatch? Visit the subscriber site, enter their e-mail
address and spread the wealth!
|
Advertising
|
To find out
how to advertise in this newsletter, e-mail David Miller or call
him
at (312) 840-8497.
The designations "National Electrical Code” and “NEC” refer to the
National Electrical Code®, which is a registered trademark of the
National Fire Protection Association.
ADVERTISEMENT

ADVERTISEMENT

|
| | | | |
|
Top 2005 Code Changes
Article 800 --
Communications Circuits, Part IV. Grounding Methods 800.100 Cable
and Primary Protector Grounding
By Mike Holt
New FPN alerts the Code user that limiting the length
of
the grounding conductor for the primary protector should reduce
voltages
that may develop between the building's power and communications
systems
during a lightning event. (Note: Code text has been
paraphrased.)
What the Code says: (A) Grounding
Conductor. The grounding conductor must be:
(4) Length. The grounding conductor must be as short as practicable. In
one- and two-family dwellings, the grounding conductor cannot exceed 20
ft.
FPN: Limiting the length of the grounding conductors reduce
differences in potential between the building's power and
communications
systems during lightning events.
Exception: Where it isn't practicable to limit the grounding
conductor to 20 ft for one- and two-family dwellings, a separate
ground rod not less than 5 ft long [800.100(B)(2)(2)] with fittings
suitable for the application [800.100(C)] must be installed. The
additional ground rod must be bonded to the power grounding electrode
system with a minimum 6 AWG conductor [800.100(D)].
ADVERTISEMENT
Achieve Your Performance Goals
Anticipate, prevent and troubleshoot motors, electrical and equipment
maintenance with fast, accurate non-contact temperature measurements
with Fluke infrared thermometers. www.fluke.com/codewatch_temp
Nightmare Installations
The Case of the
Mysterious Switch
A customer contacted us for a seemingly simple trouble
call. Having some difficulty after replacing his electric water heater,
he told us he had switched the breaker off, checked to make sure the
power was off, and then removed the old heater. After installing the
new
heater, he turned the breaker back on -- but now there was no voltage
present.
My helper and I decided to drive out to the house and check things
out. The breaker was good, but when we rang it out we discovered there
was no continuity from the panel to the new heater. There were no
junction boxes in the path! So what happened?
A trip into the attic revealed that the home run traveled down a
wall
by the kitchen sink. The hot water heater was on the floor below. A
signal from the toner found the culprit. For some reason, there was a
2-pole switch by the sink. Why, we don't know. The owner never knew
what
that switch was for -- until now (when someone in the house
inadvertently turned it off).
Greg Joachim
Kihei, Maui, Hawaii
Send your 200-word story to us, and it may
appear in a future issue of CodeWatch. Authors of stories chosen will
receive $25.
ADVERTISEMENT
Cool Electronic Cabinets
Stop electronic control downtime due to heat, dirt and moisture. UL
Listed Cabinet Coolers produce 20ºF air from an
ordinary
supply of compressed air to cool electrical controls. Thermostat
control
minimizes air usage. Maintains the NEMA 4, 4X (stainless steel) and 12
rating of the enclosure. Web site offers detailed information,
downloadable drawings and PDF literature.
www.exair.com/15/540_12a.htm
Code Challenge
What's Wrong
Here?
By Joe Tedesco
Think you know how this installation violates the NEC?
Visit EC&M's Web
site to see the answer.
Hint: Knot this time — or anytime for that matter.
Code Q&A
By Mike Holt
Q. How far away must a 120/208V, 3-phase
panelboard be located from a janitorial closet sink?
Visit EC&M's
Web site to see the answer.
Code Quiz
By Steven Owen
Q. When grounding a large bridge crane in an
industrial facility, such as a paper mill or steel mill (or any other
location), which of the following statements is correct?
A) The trolley frame and bridge frame are considered
to
be electrically grounded through the bridge and trolley wheels and its
respective track.
B) The trolley frame and bridge frame are not considered
to be electrically grounded through the bridge and trolley wheels and
its respective track.
C) All moving parts, including the trolley and bridge frame that
have a metal-to-metal bearing surface are considered to be effectively
grounded.
D) An equipment grounding conductor shall be installed along the
entire length of the crane rails, bridge, and trolley. This conductor
may be placed anywhere on the metal frame of the crane assembly.
Visit EC&M's
Web site for the answer and explanation.
ADVERTISEMENT
www.NECcode.com
The National Electrical Code Internet Connection, the No. 1
rated Code Web site in the world, offers the following FREE products:
Books, Code Quiz, DVDs, Graphics for PowerPoint, Newsletter, Online
Training, Posters, Simulated Exams, Software, Video clips, and
Videos.
Visit www.NECcode.com, and
stay
current with important industry issues.
Code News Update
Seattle Adopts 2005
NEC
Effective Oct. 22, 2005, the city of Seattle has
adopted
the 2005 edition of the National Electrical Code, according to the
November issue of electroindustry. The 2005 Seattle Electrical
Code consists of the 2005 National Electrical Code, the Washington
State
Electrical Code (WAC 96-46B), and Seattle amendments.
Approved in September by the Seattle City Council, the 2005 Seattle
Electrical Code was developed by the Electrical Code Review Committee
throughout meetings during the spring and early summer.
According to the article, a few significant amendments to the 2005
edition include:
- A new requirement for two sets of plans with applications for
equipment rated 400A or more; and for services, feeders, and power
supplies for emergency, standby and fire pump systems.
- An amendment that adds utility raceways that are metallically
connected to other service equipment to the list of equipment required
to be bonded.
- A provision allowing MC cable for branch circuits, with prior
approval of the city.
- A requirement for a standby power source kept independent of other
wiring and equipment, and separate from the same raceway, cable box, or
cabinet with wiring for low-rise shaft pressurization systems, or
elevators that are used as accessible means of egress.
|
|
You are subscribed to this newsletter as <*email*>
For questions concerning delivery of this
newsletter, please contact our Customer Service Department at:
US Toll Free: (866) 505-7173
International: (402) 505-7173
or custserv@newsletter.primediabusiness.com
Primedia Business Magazines & Media
9800 Metcalf Avenue
Overland Park, KS 66212
Copyright 2005, PRIMEDIA. All rights reserved. This article is
protected
by United States copyright and other intellectual property laws and may
not be reproduced, rewritten, distributed, re-disseminated,
transmitted,
displayed, published or broadcast, directly or indirectly, in any
medium
without the prior written permission of Primedia Business Magazines &
Media Inc.
|
|