| CONTENTS
|
250.56
Resistance of Ground Rod Electrode
What's
Wrong
Here?
Code Q&A
Code Quiz
Get In-Depth
Information on Code Changes & Standards
|
|
About this Newsletter
|
This twice-a-month e-newsletter is brought to you from the
publisher of EC&M magazine. CodeWatch will:
Let you know what could be changing in the Code®.
Help you brush up on your ability to apply the
Code®.
Test your knowledge of the Code® with a Q&A format.
Provide information on upcoming Code® seminars and
shows.
Give you an opportunity to sound off on
Code®-related
issues.
We want to make sure we're providing you with the content you need to
better manage your business or enhance your technical skills. E-mail us and let us know what
you
want to see in future issues of this e-newsletter. We will do our best
to address your request in a future issue of CodeWatch.
|
Subscriptions
|
|
To unsubscribe from this newsletter go to: Unsubscribe
To subscribe to this newsletter, go to: Subscribe
To get this newsletter in a different format (Text or HTML),
or to change your e-mail address, please visit your profile
page to change your delivery preferences.
|
Back Issues
|
|
Missed an
issue? Visit the
CodeWatch archive on EC&M's Web site.
|
Tell a friend about CodeWatch
|
|
Do you know
of someone who'd like to receive CodeWatch? Visit the subscriber site, enter
their e-mail address and spread the wealth!
|
Advertising
|
To find out
how to advertise in this newsletter, e-mail David Miller or call him at
(312) 840-8497.
The designations "National Electrical Code” and “NEC” refer to the
National Electrical Code®, which is a registered
trademark of the
National Fire Protection Association.
ADVERTISEMENT

ADVERTISEMENT

ADVERTISEMENT

|
| | | | |
|
Top 50 NEC Rules
250.56
Resistance of Ground Rod Electrode
By Mike Holt
When the resistance of a single ground rod is more than
25 ohms, an additional electrode is required to augment the first
ground
rod electrode, and it must be installed not less than 6 feet away.
However, no more than two ground rods are required -- even if the
total resistance of the two parallel ground rods exceeds 25 ohms.
You can measure the resistance of a grounding electrode with a
ground
resistance clamp meter or a 3-point fall of potential ground resistance
tester. Let's review the concepts behind each test method.
- Ground clamp meter. The ground resistance clamp meter
measures the resistance of the grounding (earthing) system by injecting
a high-frequency signal via the grounded neutral conductor to the
utility ground, and then measuring the strength of the return signal
through the earth to the grounding electrode being measured.
- Fall of potential ground resistance meter. The 3-point fall
of potential ground resistance meter determines the ground resistance
by
using Ohm's Law: R = E / I. This meter divides the voltage difference
between the electrode to be measured and a driven potential test stake
(P) by the current flowing between the electrode to be measured and a
driven current stake (C). The test stakes are typically made of
1/4-inch diameter steel rods, 24 inches long, driven two-thirds of
their
length into the earth.
The distance and alignment between the potential and current test
stakes, and the electrode, is extremely important to the validity of
the
ground resistance measurements. For an 8-foot ground rod, the accepted
practice is to space the current test stake (C) 80 feet from the
electrode to be measured.
The potential test stake (P) is positioned in a straight line between
the electrode to be measured and the current test stake (C). The
potential test stake should be located at approximately 62% of the
distance that the current test stake (C) is located from the electrode.
Since the current test stake (C) is located 80 feet from the grounding
(earthing) electrode, the potential test stake (P) will be about 50
feet
from the electrode to be measured.
The 3-point fall of potential meter can only be used to measure one
electrode at a time. Two electrodes bonded together cannot be measured
until they have been separated. The total resistance for two separate
electrodes is calculated as if they were two resistors in parallel. For
example, if the ground resistance of each electrode were 50 ohms, the
total resistance of the two electrodes bonded together is about 25
ohms.
If the electrode to be measured is connected to the electric utility
ground via the grounded neutral service conductor, the ohmmeter will
give an erroneous reading. To measure the ground resistance of
electrodes that aren't isolated from the electric utility (such as at
industrial facilities, commercial buildings, cell phone sites,
broadcast
antennas, data centers, and telephone central offices), a clamp-on
ground resistance tester would better serve the purpose.
The resistance of the grounding electrode can be lowered by bonding
multiple grounding (earthing) electrodes that are properly spaced apart
or by chemically treating the earth around the grounding (earthing)
electrode. There are many readily available commercial products for
this
purpose.
One final note on soil resistivity. The earth's ground resistance is
directly impacted by the soil's resistivity, which varies throughout
the
world. Soil resistivity is influenced by the soil's electrolytes,
which
consist of moisture, minerals, and dissolved salts. Because soil
resistivity changes with moisture content, the resistance of any
grounding (earthing) system will vary with the seasons of the year.
Since moisture becomes more stable at greater distances below the
surface of the earth, grounding (earthing) systems appear to be more
effective if the grounding electrode can reach the water table. In
addition, having the grounding electrode below the frost line helps to
ensure less deviation in the system's resistance year round.
ADVERTISEMENT
Fluke 1735 Three-Phase Power Logger
Power quality logging, electrical load studies and energy consumption
testing. The Fluke 1735 Power Logger is the ideal electrician or
technician's power meter for conducting energy studies and basic power
quality logging. Set the Power Logger up in seconds with the included
flexible current probes and color display. The power quality meter
measures most electrical power parameters, harmonics, and captures
voltage events. www.fluke.com/1735Codewatch
Code Challenge
What's Wrong Here?
By Joe Tedesco
Think you know how this installation violates the
NEC?
Visit EC&M's Web
site to see the answer.
Hint: Bad bend or lack of protection?
Code Q&A
By Mike Holt
Q. What are the NEC requirements for using
electrical metallic tubing (EMT) to physically protect NM cable?
Visit EC&M's
Web site to see the answer.
Code Quiz
By Steven Owen
Q. When sizing an equipment grounding conductor
for a solar photovoltaic system, which also has ground-fault protection
for equipment, what is the minimum size equipment grounding conductor
required for a circuit that is protected by a circuit breaker rated at
30A?
A) The ground-fault protection equipment is all that is
required.
An equipment grounding conductor is not required.
B) The minimum size of the equipment grounding conductor shall
be
based on 125% of the photovoltaic-originated short-circuit currents in
that circuit.
C) A 10 AWG conductor, as noted in Table 250.122.
D) An 8 AWG conductor, as noted in Table 250.66.
Visit EC&M's
Web site for the answer and explanation.
ADVERTISEMENT
Breakthrough Automation Available in
EasyPower® 8.0
See EasyPower's full lineup of Windows®-based electrical
power systems software tools!
New Features revolutionize the way you work:
SmartDesign automatically sizes feeders, breakers, fuses,
switchgear, busway, MCCs, panels -- and more -- all per NEC
requirements.
SmartPDC completely automates the tedious coordination of
protective devices. Verify compliance, generate impressive reports, and
ensure system reliability with one-touch automation. www.EasyPower.com
Shows and Events
Get In-Depth Information on Code
Changes & Standards
Are you a residential, industrial, commercial, or
institutional electrical contractor? Do you specify equipment or review
construction plans? Do you maintain electrical systems in a facility?
If
you answered "yes" to any of these questions, then you have to make
plans to attend the Electric West conference program in Long Beach,
Calif. Attend one of 12 fact-filled seminars -- three of which offer
CEUs. Or make plans to attend one of two update sessions on the 2005
NEC, led by top trainer Mike Holt. These Code sessions will also offer
a
sneak preview of proposed changes to the 2008 NEC. Check
out this event's 40+ seminars and make plans to meet 200+ leading
suppliers. Or register
now.

Attend Free Live Conferences at the EC&M e-Tradeshow
Don't miss these informative live conferences scheduled for January
23, 2007:
- 9:00 a.m. (Eastern and Pacific): Distributed Generation:
Products, Trends, Benefits, presented by John DeDad, senior
director, Editorial and EC&M Development. Learn about the
various
small-scale power generation technologies currently available, such as
reciprocating engines, micro-turbines, combustion gas turbines, fuel
cells, photovoltaics, and wind turbines. See respective technology
applications such as customer generation, co-generation, peak shaving,
and selling power to the grid.
- 10:00 a.m. (Eastern and Pacific):
Arc Flash Calculations
and
Distribution Analysis", presented by Bob Moore, president, Z
Meters. Learn about the beginnings of arc flash consideration, stemming
from the basic theory promoted by Ralph Lee. Find out how impedance
affects the amount of energy released from an arc flash, and how
calculations and measurement tools can help you perform your own system
analysis.
Also, enter the "Become an Electrical Inspector Contest" for a chance
to win a $100 American Express gift certificate by proving your
knowledge of the National Electrical Code and citing every Code
violation appearing in an actual electrical installation.
Visit http://ecmweb.com/etradeshow
for
information on accessing the EC&M e-Tradeshow, a virtual online
exhibition and live conference center.
And take a look at the archive of various past conferences, such as
Claim Litigation and Harmonics: Causes, Symptoms, Remediation
Techniques.
ADVERTISEMENT
Cool Electronic
Cabinets
Stop electronic control downtime due to heat, dirt and moisture. EXAIR
Cabinet Coolers produce 20 degree Fahrenheit air from an ordinary
supply
of compressed air to cool electrical controls. Thermostat control
minimizes air usage. UL Listed. Maintains the NEMA 4, 4X (stainless
steel) and 12 rating of the enclosure. Web site offers detailed
information, downloadable drawings and PDF literature.
|
|
You are subscribed to this newsletter as #email#
For questions concerning delivery of this newsletter, please contact
our
Customer Service Department at:
Customer Service Department EC&M
A Prism Business Media publication
US Toll Free: 866-505-7173
International: 847-763-9504
Email:ecmweb@pbinews.com
Prism Business Media
9800 Metcalf Avenue
Overland Park, KS 66212
Copyright 2006, Prism Business Media. All rights reserved. This article
is protected by United States copyright and other intellectual property
laws and may not be reproduced, rewritten, distributed,
re-disseminated,
transmitted,
displayed, published or broadcast, directly or indirectly, in any
medium
without the prior written permission of Prism Business Media.
|
|