210.8
─ Ground Fault Circuit Interrupter (GFCI) Protection for
Personnel
What’s Wrong
Here?
Code Q&A
Code Quiz
Speak Now, or
…
Learn About the
Changes in the 2008 National Electrical Code
|
ADVERTISEMENT

|
|
About this Newsletter
|
This twice-a-month e-newsletter is brought to you from the
publisher of EC&M magazine. CodeWatch will:
Let you know what could be changing in the Code®.
Help you brush up on your ability to apply the
Code®.
Test your knowledge of the Code® with a Q&A format.
Provide information on upcoming Code® seminars and
shows.
Give you an opportunity to sound off on
Code®-related
issues.
We want to make sure we're providing you with the content you need to
better manage your business or enhance your technical skills. E-mail us and let us know
what you want to see in future issues of this e-newsletter. We will do
our best to address your request in a future issue of CodeWatch.
|
Subscriptions
|
|
To unsubscribe from this newsletter go to: Unsubscribe
To subscribe to this newsletter, go to: Subscribe
To get this newsletter in a different format (Text or HTML),
or to change your e-mail address, please visit your profile
page to change your delivery preferences.
|
Back Issues
|
|
Missed an
issue? Visit the
CodeWatch archive on EC&M's Web site.
|
Tell a friend about CodeWatch
|
|
Do you know
of someone who'd like to receive CodeWatch? Visit the subscriber site, enter
their e-mail address and spread the wealth!
|
Advertising
|
To find out
how to advertise in this newsletter, e-mail David Miller or call him at
(312-840-8487.
The designations "National Electrical Code? and ?NEC? refer to the
National Electrical Code®, which is a registered
trademark of the
National Fire Protection Association.
ADVERTISEMENT

ADVERTISEMENT

ADVERTISEMENT

|
| | | | |
|
Top 2008 Code Changes
210.8
─ Ground Fault Circuit Interrupter (GFCI) Protection for
Personnel
By Mike Holt
Outdoor GFCI protection requirements for 15A and 20A,
125V receptacles at nondwelling unit occupancies were revised as
follows:
(B) Other Than Dwelling Units (4) Outdoors in public
spaces. All 15A and 20A, 125V receptacles installed outdoors in
public spaces ─ for the purpose of this section a public space is
defined as any space that is used for use by, or is accessible to the
public shall be GFCI-protected.
The 2005 NEC only required 15A and 20A, 125V receptacles “outdoors
in public spaces” to have GFCI protection. This change now requires
GFCI protection for these types of receptacles installed at all outdoor
locations, except as provided by the exceptions for snow-melting and
deicing equipment and industrial establishments.
ADVERTISEMENT
The Fluke 1735 Power Logger is the ideal electrician or technician's
power meter for conducting energy studies and basic power quality
logging. Set the Power Logger up in seconds with the included flexible
current probes and color display. The power quality meter measures most
electrical power parameters, harmonics, and captures voltage events. www.fluke.com/codewatch
Code Challenge
What’s Wrong Here?
By Joe Tedesco
Think you know how this installation violates the
NEC? Visit EC&M's
Web site to see the answer.
Hint: Installation doesn’t live up to this city’s
nickname
Code Q&A
By Mike Holt
Q. What are the requirements when installing a
120V switch in the same box with a 277V switch?
Visit EC&M's Web
site to see the answer.
Code Quiz
By Steven Owen
Q. When installing a concealable nonmetallic
extension from an existing 15A
non-grounding receptacle outlet in an existing dwelling unit, where
there is no
equipment grounding conductor, is it permissible to install
grounding-type receptacles
as part of the nonmetallic extension?
- Under no condition is a grounding-type receptacle permitted, as
there is no equipment grounding conductor or grounding provision
in
the existing circuit.
- Yes, if an AFCI receptacle is installed to protect all receptacle
outlets on the branch circuit.
- Yes, however, the only method permitted is the use of GFCI
receptacles.
- Yes, if grounded in accordance with 250.130(C), 406.3(D)(3)(b), or
406.3(D)(3)(c).
Visit EC&M's
Web site for the answer and explanation.
ADVERTISEMENT
Streamline the implementation of your Arc Flash and
Electrical Safety Program; what used to take days, now takes mere
seconds! Watch EasyPower in action through our online videos http://www.easypower.com/videos.php
Experience the most accurate Windows®-based tools for
designing,
analyzing, and monitoring electrical power systems: EasyPower
training will be in Portland, Oregon July 28 – August 1,
2008. This seminar fills up quickly; download a brochure
and
register by July 14th! http://www.easypower.com/support_training.php
Code News Update
Speak Now, or …
The deadline for submission of comments for the
following Reports on Proposals (ROP) is August 29, 2008.
- NFPA 99 – Standard for Health Care Facilities
- NFPA 110 – Standard for Emergency and Standby Power Systems
- NFPA 111 – Standard on Stored Electrical Energy for Emergency and
Standby Power Systems
Click
here for a direct link to each of these important documents. All
comments will be addressed.
ADVERTISEMENT
Cool Electronic Cabinets
Prevent hot weather failures that can affect production. UL Listed
Cabinet Coolers from EXAIR produce 20 degree Fahrenheit air from an
ordinary supply of compressed air to cool electrical controls.
Thermostat control minimizes air usage. Maintains the NEMA 4, 4X
(stainless steel) and 12 rating of the enclosure. Web site offers
detailed information, downloadable drawings and PDF literature.
www.exair.com/15/540_07a.htm
Shows and Events
Learn About the Changes in the 2008 National Electrical Code
In two informative and interest-filled days with Mike Holt,
you'll learn about major NEC changes that will impact your work,
whether
you're an electrician, contractor, engineer, designer, or
plant/facility
maintenance person. You'll also earn continuing education hours and
professional development hours.
Two conferences are scheduled for later this year:
--September 4-5 in Portland, Ore.
--September 8-9 in San Antonio
For more information and to register online, go to http://CodeChangeConferences.com
ADVERTISEMENT
Eliminate Red
Tags
It takes more than the UL Mark on a product to satisfy code
requirements. Before your next installation, use UL's Code Compliance
Database to identify the correlation between model codes and UL
Certified products, as well as find manufacturers of certified
products.
Click here today to
find up-to-date UL Listed products at the UL Code Correlation
Database.
|
|
You are subscribed to this newsletter as #email#
For questions concerning delivery of this newsletter, please contact
our
Customer Service Department at:
Customer Service Department EC&M
A Penton Media publication
US Toll Free: 866-505-7173
International: 847-763-9504
Email:ecmweb@pbinews.com
Penton Media | 249 W. 17th Street | New York, NY 10011
Copyright 2008, Penton Media, Inc. All rights reserved. This article is
protected by United States copyright and other intellectual property
laws and may not be reproduced, rewritten, distributed,
re-disseminated,
transmitted,
displayed, published or broadcast, directly or indirectly, in any
medium
without the prior written permission of Penton Media, Inc.
|
|