| CONTENTS
|
General
Requirements for Grounding and Bonding
What's Wrong
Here?
Code Q&A
Code Quiz
Minnesota Ready to
Adopt 2008 NEC
Learn About the
Changes in the 2008 National Electrical Code
Call for
Papers
|
ADVERTISEMENT

|
|
About this Newsletter
|
This twice-a-month e-newsletter is brought to you from the
publisher of EC&M magazine. CodeWatch will:
Let you know what could be changing in the Code®.
Help you brush up on your ability to apply the
Code®.
Test your knowledge of the Code® with a Q&A format.
Provide information on upcoming Code® seminars and
shows.
Give you an opportunity to sound off on
Code®-related
issues.
We want to make sure we're providing you with the content you need to
better manage your business or enhance your technical skills. E-mail us and let us know
what you want to see in future issues of this e-newsletter. We will do
our best to address your request in a future issue of CodeWatch.
|
Subscriptions
|
|
To unsubscribe from this newsletter go to: Unsubscribe
To subscribe to this newsletter, go to: Subscribe
To get this newsletter in a different format (Text or HTML),
or to change your e-mail address, please visit your profile
page to change your delivery preferences.
|
Back Issues
|
|
Missed an
issue? Visit the
CodeWatch archive on EC&M's Web site.
|
Tell a friend about CodeWatch
|
|
Do you know
of someone who'd like to receive CodeWatch? Visit the subscriber site, enter
their e-mail address and spread the wealth!
|
Advertising
|
To find out
how to advertise in this newsletter, e-mail David Miller or call him at
(312-840-8487.
The designations "National Electrical Code" and "NEC" refer to the
National Electrical Code®, which is a registered
trademark of the
National Fire Protection Association.
ADVERTISEMENT

ADVERTISEMENT

ADVERTISEMENT

ADVERTISEMENT

|
| | | | |
|
Top 2008 Code Changes
General
Requirements for Grounding and Bonding
By Mike Holt
A new Fine Print Note alerts Code users to the
advantage
of reducing the length of the grounding electrode conductor.
"250.4(A) Grounded Systems, (1) Electrical Systems Grounding.
Electrical power systems, such as the secondary winding of a
transformer, are grounded to the earth to limit the voltage caused by
lightning, line surges, or unintentional contact by higher-voltage
lines."
"FPN: An important consideration for limiting the imposed voltage is
the routing of bonding and grounding conductors so that they are not
any
longer than necessary to complete the connection without disturbing the
permanent parts of the installation and so that unnecessary bends and
loops are avoided."
System grounding helps reduce fires in buildings as well as voltage
stress on electrical insulation, thereby ensuring longer insulation
life
for motors, transformers, and other system components. This new Fine
Print Note is intended to call attention to the instructions contained
in Sections 800.100(A)(5), 810.21(E), and 820.100(A)(5) that grounding
conductors be run as short as possible and as straight as possible.
This
provides an effective path to earth for line surges caused by lightning
events.
ADVERTISEMENT
Demanding professionals
need our
best DMM. The 289 True-rms Logging
Multimeter with TrendCapture was designed for those of you at the top
of your field.
Large 50,000 count, 1/4 VGA display Logging function
with
expanded memory TrendCapture graphically review logged on data
Low Pass filter for adjustable speed drives
click here for more
information
Code Challenge
What's Wrong Here?
By Joe Tedesco
Think you know how this installation violates the
NEC? Visit EC&M's
Web site to see the answer.
Hint: Politics in the electrical system
Code Q&A
By Mike Holt
Q. Is a disconnect required to be within sight
of
electric space-heating equipment if the unit has a factory-installed
circuit breaker?
Visit EC&M's Web
site to see the answer.
Code Quiz
By Steven Owen
Q. According to the 2008 National Electrical
Code, electric drinking fountains installed in public buildings, such
as
schools, must meet which of the following requirements:
- Offer GFCI protection for personnel -- Class A, 5mA (nominal) trip
- Can't be supplied with a hermetic compressor
- Offer GFCI protection only if it is located within 6 feet of a 15A
or 20A, 125V single-phase receptacle outlet
- Offer GFPE protection -- Class C, 30mA trip
- none of the above
Visit EC&M's
Web site for the answer and explanation.
ADVERTISEMENT
Streamline the implementation of your Arc Flash and
Electrical Safety Program; what used to take days, now takes mere
seconds! Watch EasyPower in action through our online videos http://www.easypower.com/videos.php
Experience the most accurate Windows®-based tools for
designing, analyzing, and monitoring electrical power systems:
EasyPower training will be in Atlanta, Georgia, October 6-10,
2008. This seminar fills up quickly; download a brochure and
register by
September 22nd! http://www.easypower.com/support_training.php
Code News Update
Minnesota Ready to Adopt 2008
NEC
According to information posted on the Minnesota
Department of Labor & Industry Web site, the effective date of the 2008
National Electrical Code in the state of Minnesota will be Sept.15,
2008. All installations where the Request for Electrical Inspection is
filed with the department on or after Sept. 15, 2008 will be required
to
be in compliance with the 2008 National Electrical Code. In addition,
all electrical licensing examinations administered on or after Sept.
15, 2008 will be based on the 2008 National Electrical Code. Other
information related to the adoption of the 2008 National Electrical
Code
can be accessed at www.oah.state.mn.us/cases/190019553-electric/index.html.
ADVERTISEMENT
Cool Electronic Cabinets
Prevent hot weather failures that can affect production. UL Listed
Cabinet Coolers from EXAIR produce 20 degree Fahrenheit air from an
ordinary supply of compressed air to cool electrical controls.
Thermostat control minimizes air usage. Maintains the NEMA 4, 4X
(stainless steel) and 12 rating of the enclosure. Web site offers
detailed information, downloadable drawings and PDF literature.
www.exair.com/15/540_09a.htm
Shows and Events
Learn About the Changes in the 2008 National Electrical Code
In two informative and interest-filled days with Mike Holt,
you'll learn about major NEC changes that will impact your work,
whether
you're an electrician, contractor, engineer, designer, or
plant/facility
maintenance person. You'll also earn continuing education hours and
professional development hours.
There's still one more conference to be held this year:
--September 8-9 in San Antonio
For more information and to register online, go to http://CodeChangeConferences.com
Call for
Papers
The National Fire Protection Association (NFPA) is
accepting proposals for educational presentations at its 2009
Conference
& Expo to be held June 8-11 at McCormick Place in Chicago. The deadline
is fast approaching (September 19, 2008), but you still have time to
submit your proposal online
or download a proposal
form.
ADVERTISEMENT
Do you need guidance navigating safety standards or
want to learn about new regulations? Learn from UL experts by
attending a UL University public workshop. Featured workshops
include: CE Marking Strategies, Hazardous Locations, Specifying &
Evaluating Plastic Materials, IEC 60601-1, 2nd & 3rd Editions and many
more. Register
by September 15th with discount code ECM0908 and
receive 15% off!
|
|
You are subscribed to this newsletter as #email#
For questions concerning delivery of this newsletter, please contact
our
Customer Service Department at:
Customer Service Department EC&M
A Penton Media publication
US Toll Free: 866-505-7173
International: 847-763-9504
Email:ecmweb@pbinews.com
Penton Media | 249 W. 17th Street | New York, NY 10011
Copyright 2008, Penton Media, Inc. All rights reserved. This article is
protected by United States copyright and other intellectual property
laws and may not be reproduced, rewritten, distributed,
re-disseminated,
transmitted,
displayed, published or broadcast, directly or indirectly, in any
medium
without the prior written permission of Penton Media, Inc.
|
|