CONTENTS
|
Circuit Breakers
Motor Maintenance Tip, Part
18
Electrical Troubleshooting
Quiz
Wringing Revenue from Repairs
Fuses for Multiple Motors
NEC in the Facility
Safety
Answer to Electrical
Troubleshooting Quiz
|
|
About This Newsletter
|
This twice-a-month e-newsletter is brought to you from the
publisher of EC&M magazine. MRO Insider addresses topics such
as:
Working with management and supervision
National Electrical Code® on the production floor
Safety procedures and programs
Troubleshooting techniques
Equipment maintenance and testing tips
Managing motors and generators
Trends in training and education
Managing energy use
|
Subscriptions
|
|
To unsubscribe from this newsletter go to: Unsubscribe
To subscribe to this newsletter, go to: Subscribe
To get this newsletter in a different format (Text or HTML),
or to change your e-mail address, please visit your profile
page to change your delivery preferences.
|
Back Issues
|
|
Missed an
issue? Visit the MRO
Insider archive page on the EC&M Web site.
|
Share with a Friend
|
|
Do you know
someone who'd like to receive his or her own copy of MRO Insider? Visit
the subscriber site enter their e-mail address, and spread the wealth.
Subscribe
|
Advertising
|
To find out
how to advertise in this newsletter, e-mail David Miller or call him at
(312)
840-8487.
The designations "National Electrical Code" and "NEC" refer to the
National Electrical Code®, which is a registered
trademark of the National Fire Protection Association.
ADVERTISEMENT

ADVERTISEMENT

|
| | | | |
|
Maintenance
Circuit Breakers
Circuit breaker maintenance falls into two general
categories:
- Routine. Detection of problems via routine maintenance is
preferable to detection by any other means. The basic methods are
automated monitoring and scheduled PdM/PM.
- Major. When maintenance requires interfering with
production,
it’s “major.” So, you try to avoid doing it. When routine
maintenance reveals a problem or it’s simply the recommended time,
you
can no longer avoid major maintenance.
Examples of routine maintenance:
- Quarterly, you conduct infrared analysis and visual inspections of
your feeder panels.
- Annually, you take voltage measurements at your feeder breakers.
- Automatic ground current leakage monitoring systems activate an
alarm when ground leakage current reaches some predetermined threshold.
- Periodic reports from your power monitoring service provide
recommendations for additional maintenance based on expert analysis of
trends or events.
Routine maintenance doesn’t reduce the likelihood of major
maintenance. The real value of routine maintenance is that early
detection allows you to schedule corrective actions to prevent serious
deterioration or catastrophic failure.
Circuit breaker manufacturers provide recommended frequencies and
methods for routine maintenance. They also provide major maintenance
recommendations that address parts, procedures, frequency, and
decisions
to repair or replace. Ensure this information is referenced from (or
embedded into) your CMMS, procedures, and training.
Motor Maintenance
Tip, Part 18
Voltage imbalance kills motors. Therefore, you need to
detect and correct three types of imbalance. One type is a system-wide
voltage imbalance (we’ll look at the other two types in a future
issue).
The most common cause of system-wide voltage imbalance is
unbalanced loading. Examine all 3-phase panels to see that
the phases are wired correctly — what may appear correct on
the
panel may not be the actual A-B-C phase arrangement. Although it
may take considerable effort to track down and redistribute problem
loads, it’s a worthwhile effort.
A less common cause is the transformer taps are set wrong, resulting
in different voltages on different phases coming right out of the
transformer. The solution is to reset the taps on the transformer until
all 3-phase voltages are identical.
ADVERTISEMENT
Save on Strain Relief Grips
Starting from only $10.40 elecDirect stocks a huge variety of Mesh
Grips for wire and cable including Wide Range Strain Relief Grips.
Strain Relief Grips are used on cable to prevent pull-out, damage
from
flexing and to control arc of bend. SAME DAY SHIPPING.
elecDirect stocks more than 13,000 electrical products and tools.
Use
Coupon Code ‘MRO808’ at checkout to receive 10% off your next
order.
www.elecDirect.com
— or call toll free 800-701-0975.
Repair
Electrical
Troubleshooting Quiz
Occasionally when the big mixer starts, the
branch-circuit fuses blow. Yet, there are no shorts or other obvious
problems. If you replace the fuses, things run fine for several days.
The production superintendent wants the fuses replaced with breakers
so operators can just reset the breaker. What should you do?
The answer to this question appears at the end of this
newsletter.
Wringing Revenue
from
Repairs
Are you leaving free money on the table? Competent
production managers know the cost of each minute of downtime on each
piece of major equipment. Usually, lost revenue is the primary driver
of
that cost. Ask your production managers which equipment incurs the
highest downtime costs. Focus on speeding up repair time on that
equipment, making sure you tap a valuable resource: the manufacturer.
Manufacturers often provide downtime-reducing products. For
example:
- Assemblies. Rather than dismantle assemblies to replace a
component, you can pop out the old assembly and pop in the new one. If
an assembly isn’t presently offered, discuss this with the
manufacturer.
- Special components. See if a particular part now has an
improved version, such as “rough service” or “quick change.”
Or,
perhaps there’s a version more applicable to your application. If
these aren’t offered, discuss your problem with the manufacturer to
see what’s feasible.
- Special tools. Race car mechanics have special tools you
don’t find at any hardware store, and so should you. Manufacturers of
industrial equipment often have special jigs, fixtures, removers,
installers, and other tools that save time. If such items don’t
exist,
contact a reputable machinist to observe a repair in progress and
propose such items. You may recoup the cost of fabrication in the next
downtime event.
Fuses for Multiple
Motors
Where you have more than one motor on a branch circuit,
the maximum rating of the fuses (or breakers) protecting that branch
circuit is “the largest motor load plus.” The plus part is the sum
of the full-load current ratings of all other motors on that circuit
and
the ratings of other loads on that circuit [430.53(C)(4)].
Operation
NEC in the
Facility
During your next outage, measure the resistance between
your service transformer case(s) and any metallic items (e.g., fencing)
nearby. In each instance, you should measure the resistance of a
bonding
jumper (which is nearly zero).
If that outage is a ways off, visually check for bonding jumpers
between all metallic objects in your transformer pens. A driven rod
isn’t a bonding jumper. You want to ensure the bonding is per 250
Part
V, and the grounding is per 250 Part VI and VII [450.10].
Safety
Who should reset or replace overcurrent protection
devices (OCPDs)? It may seem harmless to let operators reset the
breaker
and call maintenance only if it trips again or won’t reset.
However, it’s not harmless. First of all, operators aren’t trained
in operation of an OCPD or disconnect. They invariably stand in the
blast path — without PPE.
If that OCPD has tripped due to a fault and the fault is still
present, anyone operating that OCPD is probably going to be severely
injured. Only a person who is qualified to test for faults and then
clear those faults should reset or replace an OCPD.
Quiz Answer
Answer to
Electrical Troubleshooting Quiz
Operators are not “qualified personnel” to work on
OCPDs — this includes resetting breakers. What the superintendent
really wants is uptime. To provide that, you need to determine
the cause of the downtime rather than be complicit in a practice that
is
both unsafe and illegal.
Are those fuses sized for the largest load plus? If not, then
recalculate for the correct size. This alone may not solve the problem.
Closely scrutinize the operation itself. Are the operators overloading
that mixer before starting it? Because the problem occurs when starting
the mixer, the solution may be as simple as starting the mixer with
less
material (or before adding material). Monitor the current draw of the
mixer under various loading scenarios before reaching any conclusions.
|
You are subscribed to this newsletter as #email#
For questions concerning delivery of this newsletter, please contact
our
Customer Service Department at:
Customer Service Department EC&M
A Penton Media publication
US Toll Free: 866-505-7173
International: 847-763-9504
Email:ecmweb@pbinews.com
Penton Media | 249 W. 17th Street | New York, NY 10011
Copyright 2008, Penton Media, Inc. All rights reserved. This article is
protected by United States copyright and other intellectual property
laws and may not be reproduced, rewritten, distributed,
re-disseminated,
transmitted,
displayed, published or broadcast, directly or indirectly, in any
medium
without the prior written permission of Penton Media, Inc.
|
|