|
CONTENTS
|
Maintaining Batteries, Part
2
Maintaining for Energy
Savings, Part 3
Electrical Troubleshooting
Quiz
Failure Frequency Analysis
NEC in the Facility
Safety
Answer to Electrical
Troubleshooting Quiz
|
|
About This Newsletter
|
This twice-a-month e-newsletter is brought to you from the
publisher of EC&M magazine. MRO Insider addresses topics such
as:
Working with management and supervision
National Electrical Code® on the production floor
Safety procedures and programs
Troubleshooting techniques
Equipment maintenance and testing tips
Managing motors and generators
Trends in training and education
Managing energy use
|
Subscriptions
|
|
To unsubscribe from this newsletter go to: Unsubscribe
To subscribe to this newsletter, go to: Subscribe
To get this newsletter in a different format (Text or HTML),
or to change your e-mail address, please visit your profile
page to change your delivery preferences.
|
Back Issues
|
|
Missed an
issue? Visit the MRO
Insider archive page on the EC&M Web site.
|
Share with a Friend
|
|
Do you know
someone who'd like to receive his or her own copy of MRO Insider? Visit
the subscriber site enter their e-mail address, and spread the wealth.
Subscribe
|
Advertising
|
To find out
how to advertise in this newsletter, e-mail David Miller or call him at
(312) 840-8487.
The designations "National Electrical Code" and "NEC" refer to the
National Electrical Code®, which is a registered
trademark of the National Fire Protection Association.
ADVERTISEMENT

|
| | | | |
|
Maintenance
Maintaining
Batteries, Part 2
To ensure your stationary batteries are there when you
need them, look closely at how your maintenance procedures address the
following practices:
- Load testing. This is a classic case of “less is more.”
Although load testing will tell you how much runtime your batteries can
provide, it reduces that runtime each time you perform this test. Some
battery experts believe the only time to load test is when submitting a
warranty claim for premature battery failure.
- Internal resistance testing. This test allows you to
quantify
the condition of your batteries. If you trend the test results, you can
proactively maintain and replace individual cells to optimize overall
battery performance.
- Thermal monitoring. Battery performance varies with
temperature, as does the charging rate. In multi-tiered batteries, each
tier will be at a different temperature and thus require a different
charging rate. Monitor the temperature of each tier.
- Charging rate analysis. This is a bit of a black art, but
well worth pursuing with a battery specialist who practices it. A
charging rate that is too high will reduce battery life, and one that
is
too low will reduce capacity.
Maintaining
for
Energy Savings, Part 3
Have you ever revised the factory settings on your HVAC
controls? If so, what procedures and references did you use? See if you
can answer the following questions:
- Do you know what the airflows are supposed to be at various
measurement points, and do you have the test equipment to test them?
- When measuring airflow in your system, are you using Pitot tubes or
electronic airflow sensors?
- Do you know the correct settings for the variable speed drives on
your blowers?
- Does your system have manual or automatic intake air vane controls?
If so (either way), how do you ensure these are positioned correctly at
any given time?
The answers to these and other questions can produce energy savings in
the way you maintain your HVAC. The manufacturers of your equipment
should be able to help you find those answers.
ADVERTISEMENT
Demanding
professionals need our best DMM. The 289 True-rms
Logging Multimeter with TrendCapture was designed for those of you at
the top of your field.
• Large 50,000 count, 1/4 VGA display • Logging function with
expanded memory • TrendCapture graphically review logged on data
• Low Pass filter for adjustable speed drives
click here for more
information
Repair
Electrical
Troubleshooting Quiz
Your plant controller mentioned at a staff meeting that
utility bills were higher than budget last summer. And that’s after
you raised the office air temperature settings by two degrees and put
locking covers on the thermostats. Now with winter setting in, you’re
under the gun to solve this before the next cooling season.
The building envelope doesn’t leak and no new equipment has been
added, so your boss thinks the HVAC system is the culprit. How can you
track down what’s going on?
The answer to this question appears at the end of this
newsletter.
Failure Frequency
Analysis
The ways to track and analyze failure frequency are
numerous and diverse. MBAs and financial types like charts laden with
cost data, and quality-control people like probability analysis.
Although these are useful tools, they don’t provide the information
most critical to the maintenance function.
You need to identify and fix the equipment failure causes, to
maximize the flow of product through the plant. Answers to two
questions
will help you:
- What are the equipment priorities based on plant safety and product
flow?
- What is the failure history of the critical equipment?
We’ll take a closer look at this in our next issue.
ADVERTISEMENT
Save on Mechanical Lugs & Splices
Starting from only $0.45, ElecDirect aluminum Mechanical Lugs & Splices
are rated for both copper and aluminum conductors. Each connector is
re-usable and needs only a hex wrench for assembly. I-Beam Lugs, Lay-In
Lugs and Panel Board Lugs are UL-Listed & CSA Certified. Great quality,
great price, fast delivery.
Use Coupon Code MRO1208 at checkout to receive 10% off your next order.
www.elecDirect.com
— or call toll free 800-701-0975.
Operation
NEC in the
Facility
Article 501 provides the requirements for Class I
locations. These are areas in which flammable gases or vapors are (or
may be) present in sufficient quantities to produce explosive or
ignitible mixtures [500.5(B)].
Class locations are further broken down into Division 1 (normal
operations) and Division 2 (abnormal operations).
- Use Division 1 wiring methods when combustibles are present under
normal operations [501.10(A)].
- Use Division 2 wiring methods when combustibles are present under
abnormal operations [501.10(B)].
Safety
Most people know that being distracted by a cell phone
while driving isn’t safe. We can probably even pick out a chatterbox
driver from a distance just by observing the traffic. Understanding why
it’s unsafe can help you stay protected while doing electrical work.
The human brain cannot multitask. When you try to do two things at
once, your brain has to switch between tasks. The switching costs are
what cause the danger.
In one study, people sat in a test room with monitoring equipment
and
took on the role of drivers. Each of them had periods of "brain
suspension," in which they didn’t process new information. It
didn’t
matter whether they were speaking into a phone or to the person next to
them. The distraction of carrying on a conversation caused lapses in
attentiveness to the primary task.
Any time you’re around electrical equipment, focus on the primary
task. If another person wants to chatter, stop working. Let that person
know you can’t work safely and listen at the same time.
Quiz Answer
Answer to
Electrical Troubleshooting Quiz
The following tests will help you quickly identify
where
the energy losses are in your HVAC system:
- Use an IR camera to examine the roof curbings for leaks.
- Use an IR camera to examine all interior ductwork, where exposed,
for leaks at the seams.
- Measure the current draw on each HVAC motor and compare to the
nominal calculated current. This is a quick way to isolate efficiency
losses. They may be due to any number of causes, both electrical and
mechanical.
- Conduct the airflow tests recommended by the manufacturer (e.g.,
airflow across the coil). Adjusting the blower speed and/or damper
position to obtain the recommended air flow can provide significant
cost-savings.
- Inspect condenser unit vanes. These are often out of sight, out of
mind. Open crushed vanes with a vane comb made for that specific type
of
vane. If the vanes are clogged with debris, clean per the
manufacturer’s approved methods.
- Check airflow around condenser units. Ensure there are no obstacles
blocking free airflow around these. For pad-mounted units at grade
level, look for vegetation, pallets, and vehicles that are in the
way.
|
You are subscribed to this newsletter as #email#
For questions concerning delivery of this newsletter, please contact
our
Customer Service Department at:
Customer Service Department EC&M
A Penton Media publication
US Toll Free: 866-505-7173
International: 847-763-9504
Email:ecmweb@pbinews.com
Penton Media | 249 W. 17th Street | New York, NY 10011
Copyright 2008, Penton Media, Inc. All rights reserved. This article is
protected by United States copyright and other intellectual property
laws and may not be reproduced, rewritten, distributed,
re-disseminated,
transmitted,
displayed, published or broadcast, directly or indirectly, in any
medium
without the prior written permission of Penton Media, Inc.
|
|